TWAL 32 ... 38 GHz
TWT Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ
W | Gain min / typ
dB | Harmonics 2nd / 3rd
dBc | Line Power VA | Dimensions (H, D)
19"-System | Weight kg |
|
TWAL 3238-230 | 32 ... 38 GHz | 230 / 250
| 53.6 / 59 ±5 | 20 / 20 | 2200 | 6 HU, 800 mm | 35 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Noise Figure | 20 dB max. | Class of Operation: | A-linear |
|
|
GENERAL
|
RF Input: | 1 ... 18 GHz | N-f; standard on rear panel | 18 ... 40 GHz | 2.92 mm-f; standard on rear panel |
| RF Output (up to 1 kW): | 1 ... 18 GHz | N-f | 6 ... 18 GHz | WRD 650 | 8 ... 18 GHz | WRD 750 | 18 ... 26,5 GHz | WR 42 | 26,5 ... 40 GHz | WR 28 |
| RF Output (1 kW or more): | 1 ... 8 GHz | 7-16-f | 8 ... 18 GHz | WRD 750 |
| Mains Supply: | 200 ... 240 V AC | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... 45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | normal laboratory environment | Cooling: | forced air with integral blower
air intake and exhaust at rear |
|
|
OPTIONS
|
A) RF Monitor Outputs *) | N) Harmonic Filter *) | B) External Dual Directional Coupler | R) RS-232C/RS-485 Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit *) | D) Front Panel RF Connectors | U) USB Remote Control | E) RF Power Indication (digital) *) | W) Liquid Cooling | F) Gain Adjustment *) | X) External Control of other Amplifiers | G) Output Isolator *) | | L) Remote Control | *) These options may reduce output power and/or gain |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|
TWAL Specifications are subject to change without notice |