BLMA  1 ... 3.2 GHz
Dual Purpose CW and Pulsed
 
STANDARD MODELS

Model
Frequency Range
CW Power
PN min / typ
W
Pulse Power
PPk min / Duty
W pk / %
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19-System
Weight

kg

BLMA 1032-500/1000P1 ... 3.2 GHz 500 / 600
1000 / 10
57 / 59 ±220 / 2038006 HU, 630 mm75

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
Dual purpose wideband CW and Pulsed Solid State Class AB Linear GaN Amplifiers
for Radiated Immunity Tests according to Automotive Standards e.g.
Ford FMC1278 | GM GMW3097 | FCA CS00054 | MBN 50284-2 | BMW GS95002-2 | VW TL81000 | Volvo STD 515-003
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Pulse Width100 µs max.
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A-linear or AB-linear
 
GENERAL

RF Input:
<12 GHzN-f, standard on rear panel
12 bis 18 GHzSMA-f, standard on front panel
>18 GHz2.92 mm-f, standard on front panel
RF Output:
<12 GHzN-f, standard on rear panel
12 to 18 GHzSMA-f, standard on front panel
>18 GHz2.92 mm-f, standard on front panel
Mains Supply:Line Power:
Line Power
<800 VA100 ... 240 V AC ±10%47 ... 63 Hz
800 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample Ports *)R) RS-232C/RS-485 Remote Control
B) External Dual Directional CouplerS) Internal RF Switching Unit *)
C) IEEE-488.2 GPIB Remote ControlU) USB Remote Control
D) Front Panel RF ConnectorsW) Liquid Cooling
E) RF Power Indication (digital) *)X) External Control of other Amplifiers
F) Gain Adjustment *)
G) Output Isolator *)*) These options may reduce output power and/or gain
H) DC Supply
I) 3x 208 V AC / 60 Hz
L) LAN Remote Control