BLMA  6 ... 8 GHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLMA 6080-306 ... 8 GHz 30 / 33
44.8 / 47 ±220 / 206003 HU, 430 mm17

BLMA 6080-506 ... 8 GHz 50 / 55
47 / 49 ±220 / 206003 HU, 430 mm22

BLMA 6080-606 ... 8 GHz 60 / 65
47.8 / 51 ±320 / 209004 HU, 630 mm38

BLMA 6080-1006 ... 8 GHz 100 / 110
50 / 53 ±320 / 2012004 HU, 630 mm40

BLMA 6080-1506 ... 8 GHz 150 / 160
51.8 / 55 ±320 / 2020004 HU, 630 mm45

BLMA 6080-2006 ... 8 GHz 200 / 220
53 / 56 ±320 / 2028005 HU, 630 mm50

BLMA 6080-5006 ... 8 GHz 500 / 550
57 / 60 ±320 / 2060008 HU, 630 mm55

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A-linear or AB-linear
 
GENERAL

RF Input:
<12 GHzN-f, standard on rear panel
12 bis 18 GHzSMA-f, standard on front panel
>18 GHz2.92 mm-f, standard on front panel
RF Output:
<12 GHzN-f, standard on rear panel
12 to 18 GHzSMA-f, standard on front panel
>18 GHz2.92 mm-f, standard on front panel
Mains Supply:Line Power:
Line Power
<800 VA100 ... 240 V AC ±10%47 ... 63 Hz
800 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample Ports *)L) LAN Remote Control
B) External Dual Directional CouplerN) Harmonics Filtering *)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit *)
E) RF Power Indication (digital) *)U) USB Remote Control
F) Gain Adjustment *)W) Liquid Cooling
G) Output Isolator *)X) External Control of other Amplifiers
H) DC Supply
I) 3x 208 V AC / 60 Hz*) These options may reduce output power and/or gain
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BLMA
Specifications are subject to change without notice