Modell
| Frequenzbereich
| Ausgangsleistung PN min / typ W | Verstärkung min / typ dB | Harmonische
2te / 3te dBc | Netzleistung VA | Abmessungen
(H, T) 19"-System | Gewicht kg |
|
BLMA 1060-0.5 | 1 ... 6 GHz | 0,5 / 0,6
| 27 / 29 ±2 | 20 / 20 | 50 | 2 HE, 430 mm | 10 |
| BLMA 1060-1 | 1 ... 6 GHz | 1 / 1,2
| 30 / 32 ±2 | 20 / 20 | 50 | 2 HE, 430 mm | 10 |
| BLMA 1060-2 | 1 ... 6 GHz | 2 / 2,5
| 33 / 35 ±2 | 20 / 20 | 70 | 2 HE, 430 mm | 10 |
| BLMA 1060-3 | 1 ... 6 GHz | 3 / 3,3
| 34,8 / 37 ±2 | 20 / 20 | 90 | 2 HE, 430 mm | 10 |
| BLMA 1060-6 | 1 ... 6 GHz | 6 / 10
| 37,8 / 40 ±2 | 15 / 20 | 160 | 2 HE, 430 mm | 10 |
| BLMA 1060-10 | 1 ... 6 GHz | 10 / 15
| 40 / 42 ±2 | 15 / 20 | 200 | 2 HE, 430 mm | 11 |
| BLMA 1060-15 | 1 ... 6 GHz | 15 / 20
| 41,8 / 45 ±3 | 20 / 20 | 250 | 2 HE, 430 mm | 12 |
| BLMA 1060-25 | 1 ... 6 GHz | 25 / 30
| 44 / 47 ±3 | 18 / 20 | 450 | 2 HE, 430 mm | 13 |
| BLMA 1060-30 | 1 ... 6 GHz | 30 / 35
| 44,8 / 48 ±3 | 18 / 20 | 550 | 2 HE, 430 mm | 14 |
| BLMA 1060-50 | 1 ... 6 GHz | 50 / 70
| 47 / 50 ±3 | 18 / 20 | 550 | 2 HE, 430 mm | 14 |
| BLMA 1060-75 | 1 ... 6 GHz | 75 / 80
| 48,8 / 52 ±3 | 18 / 20 | 950 | 3 HE, 430 mm | 22 |
| BLMA 1060-100 | 1 ... 6 GHz | 100 / 120
| 50 / 53 ±3 | 15 / 20 | 1050 | 3 HE, 430 mm | 22 |
| BLMA 1060-150 | 1 ... 6 GHz | 150 / 180
| 51,8 / 55 ±2 | 20 / 20 | 2000 | 4 HE, 630 mm | 41 |
| BLMA 1060-200/100 | 1 ... 6 GHz 1 ... 2 GHz 2 ... 4 GHz 4 ... 6 GHz | 200 / 240 180 / 240 100 / 120
| 53 / 55 ±2 53 / 55 ±2 50 / 52 ±2 | 15 / 20 20 / 20 20 / 20 | 2000 | 4 HE, 630 mm | 40 |
| BLMA 1060-200 | 1 ... 6 GHz | 200 / 220
| 53 / 56 ±3 | 20 / 20 | 3100 | 5 HE, 630 mm | 63 |
| BLMA 1060-200DS | 1 ... 6 GHz 1 ... 2,5 GHz 2,5 ... 6 GHz | 200 / 240 200 / 240
| 53 / 55 ±2 53 / 55 ±2 | 20 / 20 15 / 20 | 3000 | 12 HE, 800 mm | 110 |
| BLMA 1060-250 | 1 ... 6 GHz | 250 / 280
| 54 / 57 ±3 | 20 / 20 | 4500 | 7 HE, 630 mm | 85 |
| BLMA 1060-300/150/100D | 1 ... 6 GHz 1 ... 2,5 GHz 2,5 ... 4 GHz 4 ... 6 GHz | 300 / 320 150 / 170 100 / 120
| 54,8 / 57 ±2 51,8 / 54 ±2 50 / 52 ±2 | 15 / 20 20 / 20 20 / 20 | 2500 | 6 HE, 630 mm | 67 |
| BLMA 1060-300/200 | 1 ... 6 GHz 1 ... 4 GHz 4 ... 6 GHz | 300 / 350 200 / 220
| 54,8 / 58 ±3 53 / 56 ±3 | 20 / 20 20 / 20 | 3200 | 5 HE, 630 mm | 55 |
| BLMA 1060-300 | 1 ... 6 GHz | 300 / 320
| 54,8 / 58 ±3 | 20 / 20 | 5000 | 7 HE, 630 mm | 85 |
| BLMA 1060-400/100D | 1 ... 6 GHz 1 ... 4 GHz 4 ... 6 GHz | 400 / 450 100 / 120
| 56 / 59 ±3 50 / 53 ±3 | 20 / 20 20 / 20 | 4200 | 8 HE, 630 mm | 98 |
| BLMA 1060-400 | 1 ... 6 GHz | 400 / 450
| 56 / 59 ±3 | 20 / 20 | 6500 | 10 HE, 630 mm | 121 |
| BLMA 1060-500 | 1 ... 6 GHz | 500 / 550
| 57 / 60 ±3 | 18 / 20 | 7000 | 12 HE, 800 mm | 153 |
| BLMA 1060-750 | 1 ... 6 GHz | 750 / 800
| 58,8 / 62 ±3 | 15 / 20 | 10000 | 18 HE, 800 mm | 190 |
| BLMA 1060-1000/300D | 1 ... 6 GHz 1 ... 3,2 GHz 3,2 ... 6 GHz | 1000 / 1100 300 / 350
| 60 / 63 ±3 54,8 / 58 ±3 | 15 / 20 15 / 20 | 13500 | 24 HE, 800 mm | 260 |
| BLMA 1060-1000 | 1 ... 6 GHz | 1000 / 1100
| 60 / 63 ±3 | 15 / 20 | 15000 | 24 HE, 800 mm | 260 |
|
|
HF-Eingang: | <12 GHz | N-f, standardmäßig auf der Rückseite | 12 bis 18 GHz | SMA-f, standardmäßig auf der Frontseite | >18 GHz | 2.92 mm-f, standardmäßig auf der Frontseite |
| HF-Ausgang: | <12 GHz | N-f, standardmäßig auf der Rückseite | 12 bis 18 GHz | SMA-f, standardmäßig auf der Frontseite | >18 GHz | 2.92 mm-f, standardmäßig auf der Frontseite |
| Spannungsversorgung: | Netzleistung | | | <800 VA | 100 ... 240 V AC ±10% | 47 ... 63 Hz | 800 ... 3000 VA | 200 ... 240 V AC ±10% | 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% | 47 ... 63 Hz |
| Betriebsstundenzähler: | im Status-Display | Betriebstemperatur: | 0 ... +45 °C | Lagertemperatur: | -20 ... +85 °C | Rel. Luftfeuchtigkeit: | bis 95% (ohne Kondensation) | Betriebshöhe: | bis 2000 m über NN | Vibration und Schock: | MIL-STD-810 G | Kühlung: | Ventilatorkühlung
Lufteinlaß vorne, Luftauslaß hinten |
|