BPA 1 ... 1.1 GHz
Pulsed Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PP min / Duty W pk / % | Pulse Width max. **)
| Gain typ
dB | Harmonics
2nd / 3rd
dBc | Line Power VA | Dimensions
(H, D)
19"-System | Weight kg |
|
BPA 1011-1000 | 1 ... 1.1 GHz | 1000 / 10
| 100 µs | 60 ±2 | 30 / 30 | 600 | 3 HU, 630 mm | 22 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| PRF at 1 µs Pulswidth | 100 kHz (Duty 6 ... 10%) | PRF at 100 µs Pulswidth | 1 kHz (Duty 6 ... 10%) | Pulse Droop: | 1.0 dB max. | Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | C |
|
|
GENERAL
|
RF Input: | <8 GHz | N-f , standard on rear panel | 8 to 18 GHz | SMA-f, standard on front panel | > 18 GHz | K-f, standard on front panel |
| RF Output: | <8 GHz | N-f, standard on rear panel | 8 to 18 GHz | SMA-f, standard on front panel | >18 GHz | K-f, standard on front panel |
| Mains Supply: | PP up to 100 W | 85 ... 264 V AC | 47 ... 63 Hz | PP >100 W | 3x 400 V AC | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) Sample Ports *) | R) RS-232C/RS-485 Remote Control | B) External Dual Directional Coupler | S) Internal RF Switching Unit *) | C) IEEE-488.2 GPIB Remote Control | U) USB Remote Control | D) Front Panel RF-Connectors | W) Liquid Cooling | E) RF Power Indication (digital) *) | X) External Control of other Amplifiers | F) Gain Adjustment *) | | G) Output Isolator *) | *) These options may reduce output power and/or gain | H) DC-Supply | **) Optionally other pulse width available | I) 3x 208 V AC / 60 Hz | | |