BSA  9 kHz ... 225 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BSA 0122-10009 kHz ... 225 MHz 1000 / 1100
60 / 62 ±220 / 2040005 HU, 630 mm65

BSA 0122-1000W9 kHz ... 225 MHz 1000 / 1100
60 / 62 ±220 / 2040004 HU, 630 mm65

BSA 0122-15009 kHz ... 225 MHz 1500 / 1700
61.8 / 64 ±220 / 181000015 HU, 630 mm200

BSA 0122-20009 kHz ... 225 MHz 2000 / 2200
63 / 65 ±220 / 201300021 HU, 800 mm205

BSA 0122-2000W9 kHz ... 225 MHz 2000 / 2200
63 / 65 ±220 / 201300018 HU, 800 mm205

BSA 0122-30009 kHz ... 225 MHz 3000 / 3300
64.8 / 67 ±220 / 201400024 HU, 800 mm265

BSA 0122-3000W9 kHz ... 225 MHz 3000 / 3300
64.8 / 67 ±220 / 201400018 HU, 800 mm265

BSA 0122-5000/40009 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

5000 / 5500
4000 / 5000

67 / 70 ±3
67 / 70 ±3

20 / 20
20 / 20
3000037 HU, 800 mm (XL)600

BSA 0122-5000/4000W9 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

5000 / 5500
4000 / 5000

67 / 70 ±3
67 / 70 ±3

20 / 20
20 / 20
3000037 HU, 800 mm600

BSA 0122-50009 kHz ... 225 MHz 5000 / 5500
67 / 70 ±320 / 203000037 HU, 800 mm (XL)600

BSA 0122-5000W9 kHz ... 225 MHz 5000 / 5500
67 / 70 ±320 / 203000037 HU, 800 mm600

BSA 0122-100009 kHz ... 225 MHz 10000 / 11000
70 / 73 ±320 / 20550002x 37 HU, 800 mm (XL)1100

BSA 0122-10000W9 kHz ... 225 MHz 10000 / 11000
70 / 73 ±320 / 20550002x 37 HU, 800 mm1100

BSA 0122-10000/80009 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

10000 / 11000
8000 / 10000

70 / 73 ±3
70 / 73 ±3

20 / 20
20 / 20
550002x 37 HU, 800 mm (XL)1100

BSA 0122-10000/8000W9 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

10000 / 11000
8000 / 10000

70 / 73 ±3
70 / 73 ±3

20 / 20
20 / 20
550002x 37 HU, 800 mm1100

BSA 0122-12000/100009 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

12000 / 13000
10000 / 11000

70 / 73 ±3
70 / 73 ±3

20 / 20
20 / 20
550002x 37 HU, 800 mm (XL)1100

BSA 0122-12000/10000W9 kHz ... 225 MHz
9 kHz ... 100 MHz
100 ... 225 MHz

12000 / 13000
10000 / 11000

70 / 73 ±3
70 / 73 ±3

20 / 20
20 / 20
550002x 37 HU, 800 mm1100

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
<1 kWN-f
<3 kW7-16-f
<5 kWEIA 1 5/8
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10% / 47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10% / 47 ... 63 Hz
>3000 VA3x 400 V AC ±10% / 47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
Option W: Liquid cooling
External heat exchanger required
 
OPTIONS

A) RF Monitor OutputsL) LAN Remote Control
B) External Dual Directional CouplerR) RS-232C/RS-485 Remote Control
C) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching Unit
D) Front Panel RF ConnectorsU) USB Remote Control
E) RF Power Indication (digital)W) Liquid Cooling
F) Gain AdjustmentX) External Control of other Amplifiers
H) DC Supply(XL) Rack width 800 mm
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BSA
Specifications are subject to change without notice