BSA 9 kHz ... 6000 MHz
Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ
W | Gain min / typ
dB | Harmonics
2nd / 3rd
dBc | Line Power VA | Dimensions
(H, D)
19"-System | Weight kg |
|
BSA 0106-25/10D | 9 kHz ... 6000 MHz 9 kHz ... 250 MHz 200 ... 1000 MHz 1000 ... 6000 MHz | 25 / 30 25 / 30 10 / 15
| 44 / 46 ±2 44 / 46 ±2 40 / 43 ±3 | 20 / 20 20 / 20 20 / 20 | 240 | 3 HU, 430 mm | 18 |
| BSA 0106-25D | 9 kHz ... 6000 MHz 9 kHz ... 500 MHz 500 ... 6000 MHz | 25 / 30 25 / 30
| 44 / 46 ±2 44 / 47 ±3 | 20 / 20 20 / 20 | 420 | 3 HU, 430 mm | 19 |
| BSA 0106-75D | 9 kHz ... 6000 MHz 9 kHz ... 400 MHz 400 ... 1000 MHz 1000 ... 6000 MHz | 75 / 85 75 / 85 75 / 85
| 48.8 / 51 ±2 48.8 / 51 ±2 48.8 / 52 ±3 | 20 / 20 20 / 20 18 / 20 | 1000 | 3 HU, 630 mm | 32 |
| BSA 0106-100D | 9 kHz ... 6000 MHz 9 kHz ... 400 MHz 400 ... 1000 MHz 1000 ... 6000 MHz | 100 / 110 100 / 110 100 / 110
| 50 / 52 ±2 50 / 52 ±2 50 / 53 ±3 | 20 / 20 20 / 20 18 / 20 | 1500 | 4 HU, 630 mm | 45 |
| BSA 0106-200D | 9 kHz ... 6000 MHz 9 kHz ... 400 MHz 400 ... 1000 MHz 1000 ... 6000 MHz | 200 / 220 200 / 220 200 / 220
| 53 / 55 ±2 53 / 55 ±2 53 / 56 ±3 | 20 / 20 20 / 20 20 / 20 | 3200 | 8 HU, 630 mm | 82 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A linear or A-B linear |
|
|
GENERAL
|
RF Input: | N-f, standard on rear panel | RF Output: | standard on rear panel
<1 kW | N-f | <3 kW | 7-16-f | <5 kW | EIA 1 5/8 |
| Mains Supply: | Line Power:
<1000 VA | 100 ... 240 V AC ±10% / 47 ... 63 Hz | 1000 ... 3000 VA | 200 ... 240 V AC ±10% / 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% / 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -25 ... 85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower air intake from front, air exhaust at rear Option W: Liquid cooling External heat exchanger required |
|
|
OPTIONS
|
A) RF Monitor Outputs | L) LAN Remote Control | B) External Dual Directional Coupler | R) RS-232C/RS-485 Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit | D) Front Panel RF Connectors | U) USB Remote Control | E) RF Power Indication (digital) | W) Liquid Cooling | F) Gain Adjustment | X) External Control of other Amplifiers | H) DC Supply | (XL) Rack width 800 mm |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|
BSA Specifications are subject to change without notice |