BSA  100 kHz ... 1000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BSA 1001-30D100 kHz ... 1000 MHz
100 kHz ... 100 MHz
100 ... 1000 MHz

30 / 35
30 / 35

44.8 / 47 ±2
44.8 / 47 ±2

20 / 20
20 / 20
2502 HU, 430 mm15

BSA 1001-50/75D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

50 / 70
75 / 100

47 / 49 ±2
48.8 / 51 ±2

20 / 20
20 / 20
4803 HU, 630 mm22

BSA 1001-75D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

75 / 100
75 / 100

48.8 / 51 ±2
48.8 / 51 ±2

20 / 20
20 / 20
6003 HU, 630 mm24

BSA 1001-100D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

100 / 120
100 / 120

50 / 52 ±2
50 / 52 ±2

20 / 20
20 / 20
5503 HU, 630 mm24

BSA 1001-150/100D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

150 / 170
100 / 120

51.8 / 54 ±2
50 / 52 ±2

20 / 20
20 / 20
7003 HU, 630 mm24

BSA 1001-250D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

250 / 300
250 / 300

54 / 56 ±2
54 / 56 ±2

20 / 20
20 / 20
21004 HU, 630 mm45

BSA 1001-300D100 kHz ... 1000 MHz
100 kHz ... 400 MHz
400 ... 1000 MHz

300 / 350
300 / 330

54.8 / 57 ±2
54.8 / 57 ±2

20 / 20
20 / 20
22004 HU, 630 mm46

BSA 1001-500/300D100 kHz ... 1000 MHz
100 kHz ... 250 MHz
250 ... 400 MHz
400 ... 1000 MHz

500 / 550
300 / 350
300 / 350

57 / 59 ±2
54.8 / 57 ±2
54.8 / 57 ±2

20 / 18
20 / 20
20 / 20
25004 HU, 630 mm46

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
<1 kWN-f
<3 kW7-16-f
<5 kWEIA 1 5/8
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10% / 47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10% / 47 ... 63 Hz
>3000 VA3x 400 V AC ±10% / 47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-20 ... +85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
Option W: Liquid cooling
External heat exchanger required
 
OPTIONS

A) RF Monitor OutputsL) LAN Remote Control
B) External Dual Directional CouplerR) RS-232C/RS-485 Remote Control
C) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching Unit
D) Front Panel RF ConnectorsU) USB Remote Control
E) RF Power Indication (digital)W) Liquid Cooling
F) Gain AdjustmentX) External Control of other Amplifiers
H) DC Supply(XL) Rack width 800 mm
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BSA
Specifications are subject to change without notice