TWAP 3 ... 4 GHz
Pulsed TWT Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PP min / Duty
W / % | Pulse Width max. **)
| Gain typ
dB | Harmonics 2nd / 3rd dBc | Line Power VA | Dimensions (H, D)
19"-System | Weight kg |
|
TWAP 0304-9000 | 2.9 ... 4 GHz | 9000 / 4
| 50 µs | 77.5 ±7.5 | 6 / 15 | 2000 | 6 HU, 800 mm | 48 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| PRF at 1 µs Pulswidth: | 100 kHz (Duty e.g. 6%) | PRF at 100 µs Pulswidth: | 1 kHz (Duty e.g. 6%) | Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A-linear |
|
|
GENERAL
|
RF Input: | <8 GHz | N-f, standard on rear panel | 8 to 18 GHz | SMA-f, standard on front panel | >18 GHz | 2.92 mm-f, standard on front panel |
| RF Output: | <8 GHz | 7-16-f, standard on rear panel | 4 to 8 GHz | WRD 350, standard on rear panel | 8 to 12 GHz | WR 90, standard on rear panel | 8 to 18 GHz | WRD 750, standard on rear panel | 12 to 18 GHz | WR 62, standard on rear panel |
| Mains Supply: | PLine up to 3 kVA | 200 ... 240 V AC | 47 ... 63 Hz | PLine >3 kVA | 3x 400 V AC | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) Sample Ports *) | L) LAN Remote Control | B) External Dual Directional Coupler | R) RS-232C/RS-485 Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit *) | D) Front Panel RF Connectors | U) USB Remote Control | E) RF Power Indication (digital) *) | W) Liquid Cooling | F) Gain Adjustment *) | X) External Control of other Amplifiers | G) Output Isolator *) | | H) DC Supply | *) These options may reduce output power and/or gain | I) 3x 208 V AC / 60 Hz | **) Optionally other pulse width available | |