Narrow Band Amplifiers 1.8 ... 2 GHz
Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ W | Gain min / typ dB | Harmonics
2nd / 3rd dBc | Line Power VA | Dimensions
(H, D) 19"-System | Weight kg |
|
BLMA 1820-120 | 1.8 ... 2 GHz | 120 / 140
| 51 / 53 ±2 | 50 / 50 | 750 | 4 HU, 630 mm | 27 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A-linear or AB-linear |
|
|
GENERAL
|
RF Input: | <12 GHz | N-f, standard on rear panel | 12 bis 18 GHz | SMA-f, standard on front panel | >18 GHz | 2.92 mm-f, standard on front panel |
| RF Output: | <12 GHz | N-f, standard on rear panel | 12 to 18 GHz | SMA-f, standard on front panel | >18 GHz | 2.92 mm-f, standard on front panel |
| Mains Supply: | Line Power:
Line Power | | | <800 VA | 100 ... 240 V AC ±10% | 47 ... 63 Hz | 800 ... 3000 VA | 200 ... 240 V AC ±10% | 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -25 ... 85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) RF-Sample Ports *) | L) LAN Remote Control | B) External Dual Directional Coupler | N) Harmonics Filtering *) | C) IEEE-488.2 GPIB Remote Control | R) RS-232C/RS-485 Remote Control | D) Front Panel RF Connectors | S) Internal RF Switching Unit *) | E) RF Power Indication (digital) *) | U) USB Remote Control | F) Gain Adjustment *) | W) Liquid Cooling | G) Output Isolator *) | X) External Control of other Amplifiers | H) DC Supply | | I) 3x 208 V AC / 60 Hz | *) These options may reduce output power and/or gain |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|
BLMA Specifications are subject to change without notice |