BLWA  80 ... 6000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 0860-10D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

10 / 12
10 / 12

40 / 42 ±2
40 / 42 ±2

20 / 20
20 / 20
2702 HU, 430 mm14

BLWA 0860-30D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

30 / 35
30 / 35

44.8 / 47 ±2
44.8 / 47 ±2

20 / 20
15 / 20
5003 HU, 430 mm15

BLWA 0860-50/20D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

50 / 60
20 / 30

47 / 49 ±2
43 / 46 ±3

20 / 20
15 / 20
6003 HU, 430 mm18

BLWA 0860-50D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

50 / 60
50 / 55

47 / 49 ±2
47 / 50 ±3

20 / 20
18 / 20
6003 HU, 430 mm21

BLWA 0860-150/50D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

150 / 180
50 / 55

51.8 / 54 ±2
47 / 50 ±3

20 / 20
15 / 20
12504 HU, 630 mm37

BLWA 0860-150D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

150 / 180
150 / 180

51.8 / 54 ±2
51.8 / 55 ±3

20 / 20
15 / 20
21006 HU, 630 mm64

BLWA 0860-250/100/50D80 ... 6000 MHz
80 ... 400 MHz
400 ... 2500 MHz
2500 ... 6000 MHz

250 / 300
100 / 120
50 / 55

54 / 56 ±2
50 / 53 ±3
47 / 50 ±3

20 / 20
15 / 20
15 / 20
14004 HU, 630 mm37

BLWA 0860-250/100D80 ... 6000 MHz
80 ... 1000 MHz
1000 ... 6000 MHz

250 / 300
100 / 120

54 / 56 ±2
50 / 53 ±3

20 / 20
15 / 20
16504 HU, 630 mm42

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsL) LAN Remote Control
B) External Dual Directional CouplerP) Precise RMS RF Power Sensor (internal)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers