BLWA  500 ... 1000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 5010-100500 ... 1000 MHz 100 / 120
50 / 52 ±220 / 205003 HU, 630 mm18

BLWA 5010-125500 ... 1000 MHz 125 / 140
51 / 53 ±220 / 205003 HU, 630 mm20

BLWA 5010-200500 ... 1000 MHz 200 / 230
53 / 55 ±220 / 2011503 HU, 630 mm25

BLWA 5010-250500 ... 1000 MHz 250 / 300
54 / 56 ±220 / 2018003 HU, 630 mm32

BLWA 5010-350500 ... 1000 MHz 350 / 400
55.4 / 58 ±220 / 2022004 HU, 630 mm32

BLWA 5010-500500 ... 1000 MHz 500 / 600
57 / 59 ±220 / 2032005 HU, 630 mm50

BLWA 5010-700500 ... 1000 MHz 700 / 750
58.5 / 61 ±220 / 2040008 HU, 630 mm82

BLWA 5010-1000500 ... 1000 MHz 1000 / 1150
60 / 62 ±220 / 2045008 HU, 630 mm85

BLWA 5010-1250500 ... 1000 MHz 1250 / 1300
61 / 63 ±220 / 20600018 HU, 800 mm150

BLWA 5010-1500500 ... 1000 MHz 1500 / 1700
61.8 / 64 ±220 / 20750018 HU, 800 mm150

BLWA 5010-2000500 ... 1000 MHz 2000 / 2200
63 / 65 ±220 / 201500024 HU, 800 mm280

BLWA 5010-3000500 ... 1000 MHz 3000 / 3300
64.8 / 67 ±220 / 201800024 HU, 800 mm280

BLWA 5010-4000500 ... 1000 MHz 4000 / 4500
66 / 68 ±220 / 202800037 HU, 800 mm450

BLWA 5010-5000500 ... 1000 MHz 5000 / 5500
67 / 69 ±220 / 203400037 HU, 800 mm450

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-20 ... +85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsI) 3x 208 V AC / 60 Hz
B) External Dual Directional CouplerL) LAN Remote Control
C) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching Unit
D) Front Panel RF ConnectorsR) RS-232C/RS-485 Remote Control
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BLWA
Specifications are subject to change without notice