BLWA  400 ... 1000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 4010-100400 ... 1000 MHz 100 / 120
50 / 52 ±220 / 205003 HU, 630 mm18

BLWA 4010-125400 ... 1000 MHz 125 / 140
51 / 53 ±220 / 205803 HU, 630 mm22

BLWA 4010-200400 ... 1000 MHz 200 / 230
53 / 55 ±220 / 2011503 HU, 630 mm25

BLWA 4010-250400 ... 1000 MHz 250 / 300
54 / 56 ±220 / 2018004 HU, 630 mm35

BLWA 4010-350400 ... 1000 MHz 350 / 400
55.4 / 58 ±220 / 2022004 HU, 630 mm35

BLWA 4010-500400 ... 1000 MHz 500 / 600
57 / 59 ±220 / 2032005 HU, 630 mm50

BLWA 4010-700400 ... 1000 MHz 700 / 750
58.5 / 61 ±220 / 2040008 HU, 630 mm82

BLWA 4010-1000400 ... 1000 MHz 1000 / 1150
60 / 62 ±220 / 2045008 HU, 630 mm85

BLWA 4010-1250400 ... 1000 MHz 1250 / 1300
61 / 63 ±220 / 20600018 HU, 800 mm150

BLWA 4010-1500400 ... 1000 MHz 1500 / 1700
61.8 / 64 ±220 / 20750018 HU, 800 mm150

BLWA 4010-2000400 ... 1000 MHz 2000 / 2200
63 / 65 ±220 / 201500024 HU, 800 mm280

BLWA 4010-3000400 ... 1000 MHz 3000 / 3300
64.8 / 67 ±220 / 201800024 HU, 800 mm280

BLWA 4010-4000400 ... 1000 MHz 4000 / 4500
66 / 68 ±220 / 202800037 HU, 800 mm450

BLWA 4010-5000400 ... 1000 MHz 5000 / 5500
67 / 69 ±220 / 203400037 HU, 800 mm450

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsL) LAN Remote Control
B) External Dual Directional CouplerP) Precise RMS RF Power Sensor (internal)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers