BLWA 400 ... 450 MHz
Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ
W | Gain min / typ
dB | Harmonics 2nd / 3rd
dBc | Line Power VA | Dimensions
(H, D)
19"-System | Weight kg |
|
BLWA 4045-250 | 400 ... 450 MHz | 250 / 300
| 54 / 55 ±1 | 15 / 15 | 1000 | 4 HU, 630 mm | 38 |
| BLWA 4045-500 | 400 ... 450 MHz | 500 / 600
| 57 / 58 ±1 | 15 / 15 | 2000 | 5 HU, 630 mm | 48 |
| BLWA 4045-1000 | 400 ... 450 MHz | 1000 / 1100
| 60 / 61 ±1 | 15 / 15 | 4000 | 6 HU, 630 mm | 62 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A linear or A-B linear |
|
|
GENERAL
|
RF Input: | N-f, standard on rear panel | RF Output: | standard on rear panel
PN up to 1 kW | N-f | PN >1 kW | 7-16-f | PN >2 kW | 13-30-f or 1 5/8"EIA |
| Mains Supply: | Line Power:
<1000 VA | 100 ... 240 V AC ±10% | 47 ... 63 Hz | 1000 ... 3000 VA | 200 ... 240 V AC ±10% | 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) RF-Sample Ports | I) 3x 208 V AC / 60 Hz | B) External Dual Directional Coupler | L) LAN Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit | D) Front Panel RF Connectors | R) RS-232C/RS-485 Remote Control | E) RF Power Indication (digital) | U) USB Remote Control | F) Gain Adjustment | W) Liquid Cooling | H) DC Supply | X) External Control of other Amplifiers |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|
BLWA Specifications are subject to change without notice |