BLWA  200 ... 500 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 2050-100200 ... 500 MHz 100 / 120
50 / 52 ±220 / 154003 HU, 430 mm19

BLWA 2050-150200 ... 500 MHz 150 / 180
51.8 / 54 ±220 / 158003 HU, 430 mm24

BLWA 2050-300200 ... 500 MHz 300 / 330
54.8 / 57 ±220 / 2015003 HU, 630 mm35

BLWA 2050-500200 ... 500 MHz 500 / 600
57 / 59 ±220 / 2025005 HU, 630 mm43

BLWA 2050-750200 ... 500 MHz 750 / 850
58.8 / 61 ±220 / 2040006 HU, 630 mm80

BLWA 2050-1000200 ... 500 MHz 1000 / 1150
60 / 62 ±220 / 2060009 HU, 630 mm95

BLWA 2050-1500200 ... 500 MHz 1500 / 1700
61.8 / 64 ±220 / 20800016 HU, 630 mm180

BLWA 2050-2000200 ... 500 MHz 2000 / 2200
63 / 65 ±220 / 201000019 HU, 630 mm200

BLWA 2050-2500200 ... 500 MHz 2500 / 2700
64 / 66 ±220 / 201700041 HU, 800 mm300

BLWA 2050-3500200 ... 500 MHz 3500 / 4000
65.4 / 68 ±220 / 202000041 HU, 800 mm400

BLWA 2050-4500200 ... 500 MHz 4500 / 5000
65.5 / 68 ±220 / 20350002x 37 HU, 800 mm600

BLWA 2050-6000200 ... 500 MHz 6000 / 6500
67.8 / 70 ±220 / 20450002x 37 HU, 800 mm600

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsL) LAN Remote Control
B) External Dual Directional CouplerP) Precise RMS RF Power Sensor (internal)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers