BLWA 100 ... 500 MHz
Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ
W | Gain min / typ
dB | Harmonics 2nd / 3rd
dBc | Line Power VA | Dimensions
(H, D)
19"-System | Weight kg |
|
BLWA 1050-100 | 100 ... 500 MHz | 100 / 120
| 50 / 52 ±2 | 20 / 12 | 400 | 3 HU, 430 mm | 19 |
| BLWA 1050-150 | 100 ... 500 MHz | 150 / 180
| 51.8 / 54 ±2 | 20 / 20 | 800 | 3 HU, 430 mm | 24 |
| BLWA 1050-250 | 100 ... 500 MHz | 250 / 300
| 54 / 56 ±2 | 20 / 20 | 1500 | 3 HU, 630 mm | 35 |
| BLWA 1050-500 | 100 ... 500 MHz | 500 / 600
| 57 / 59 ±2 | 20 / 20 | 3000 | 4 HU, 630 mm | 44 |
| BLWA 1050-750 | 100 ... 500 MHz | 750 / 900
| 58.8 / 61 ±2 | 20 / 20 | 4500 | 8 HU, 630 mm | 80 |
| BLWA 1050-1000 | 100 ... 500 MHz | 1000 / 1150
| 60 / 62 ±2 | 20 / 20 | 6500 | 9 HU, 630 mm | 95 |
| BLWA 1050-1500 | 100 ... 500 MHz | 1500 / 1700
| 61.8 / 64 ±2 | 20 / 20 | 10000 | 21 HU, 800 mm | 200 |
| BLWA 1050-2000 | 100 ... 500 MHz | 2000 / 2200
| 63 / 65 ±2 | 20 / 20 | 17000 | 41 HU, 800 mm | 300 |
| BLWA 1050-2500 | 100 ... 500 MHz | 2500 / 2700
| 64 / 66 ±2 | 20 / 20 | 20000 | 41 HU, 800 mm | 400 |
| BLWA 1050-4000 | 100 ... 500 MHz | 4000 / 4400
| 66 / 68 ±2 | 20 / 20 | 35000 | 2x 37 HU, 800 mm | 600 |
| BLWA 1050-5000 | 100 ... 500 MHz | 5000 / 5500
| 67 / 69 ±2 | 20 / 20 | 45000 | 2x 37 HU, 800 mm | 800 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A linear or A-B linear |
|
|
GENERAL
|
RF Input: | N-f, standard on rear panel | RF Output: | standard on rear panel
PN up to 1 kW | N-f | PN >1 kW | 7-16-f | PN >2 kW | 13-30-f or 1 5/8"EIA |
| Mains Supply: | Line Power:
<1000 VA | 100 ... 240 V AC ±10% | 47 ... 63 Hz | 1000 ... 3000 VA | 200 ... 240 V AC ±10% | 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) RF-Sample Ports | I) 3x 208 V AC / 60 Hz | B) External Dual Directional Coupler | L) LAN Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit | D) Front Panel RF Connectors | R) RS-232C/RS-485 Remote Control | E) RF Power Indication (digital) | U) USB Remote Control | F) Gain Adjustment | W) Liquid Cooling | H) DC Supply | X) External Control of other Amplifiers |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|