BLWA  80 ... 2000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 0820-150D80 ... 2000 MHz
80 ... 500 MHz
500 ... 2000 MHz

150 / 180
150 / 180

51.8 / 54 ±2
51.8 / 54 ±2

20 / 15
15 / 20
9005 HU, 630 mm38

BLWA 0820-250/100/30D80 ... 2000 MHz
80 ... 400 MHz
400 ... 1000 MHz
1000 ... 2000 MHz

250 / 300
100 / 150
30 / 35

54 / 56 ±2
50 / 52 ±2
44.8 / 47 ±2

20 / 20
20 / 20
20 / 20
10004 HU, 630 mm36

BLWA 0820-250/100/60D80 ... 2000 MHz
80 ... 400 MHz
400 ... 1000 MHz
1000 ... 2000 MHz

250 / 300
100 / 150
60 / 70

54 / 56 ±2
50 / 52 ±2
47.8 / 50 ±2

20 / 20
20 / 20
20 / 20
10004 HU, 630 mm38

BLWA 0820-250/200D80 ... 2000 MHz
80 ... 500 MHz
500 ... 2000 MHz

250 / 300
200 / 240

54 / 56 ±2
53 / 56 ±3

20 / 15
15 / 15
12504 HU, 630 mm39

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-20 ... +85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsI) 3x 208 V AC / 60 Hz
B) External Dual Directional CouplerL) LAN Remote Control
C) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching Unit
D) Front Panel RF ConnectorsR) RS-232C/RS-485 Remote Control
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BLWA
Specifications are subject to change without notice