BLWA  20 ... 1000 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 021O-120 ... 1000 MHz 1 / 1.5
30 / 32 ±220 / 20752 HU, 430 mm11

BLWA 021O-320 ... 1000 MHz 3 / 3.5
34.8 / 37 ±220 / 201002 HU, 430 mm11

BLWA 021O-520 ... 1000 MHz 5 / 6
37 / 39 ±220 / 201202 HU, 430 mm12

BLWA 021O-1020 ... 1000 MHz 10 / 12
40 / 42 ±220 / 201302 HU, 430 mm12

BLWA 021O-3020 ... 1000 MHz 30 / 35
44.8 / 47 ±220 / 202302 HU, 430 mm12

BLWA 021O-4020 ... 1000 MHz 40 / 45
46 / 48 ±220 / 203002 HU, 430 mm13

BLWA 021O-5020 ... 1000 MHz 50 / 60
48 / 50 ±220 / 203302 HU, 430 mm13

BLWA 021O-10020 ... 1000 MHz 100 / 120
50 / 52 ±220 / 209003 HU, 630 mm26

BLWA 021O-15020 ... 1000 MHz 150 / 200
51.8 / 54 ±220 / 2021004 HU, 630 mm40

BLWA 021O-30020 ... 1000 MHz 300 / 330
54.8 / 57 ±220 / 1530004 HU, 630 mm42

BLWA 021O-50020 ... 1000 MHz 500 / 550
57 / 59 ±220 / 1540008 HU, 630 mm58

BLWA 021O-350/200/100D20 ... 1000 MHz
20 ... 100 MHz
100 ... 400 MHz
400 ... 1000 MHz

350 / 400
200 / 220
100 / 120

55.4 / 58 ±2
53 / 55 ±2
50 / 52 ±2

20 / 15
20 / 15
20 / 20
10008 HU, 630 mm60

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsL) LAN Remote Control
B) External Dual Directional CouplerP) Precise RMS RF Power Sensor (internal)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers