BLWA 20 ... 500 MHz
Solid State Amplifiers |
|
|
STANDARD MODELS
|
Model
| Frequency Range
| Output Power PN min / typ
W | Gain min / typ
dB | Harmonics 2nd / 3rd
dBc | Line Power VA | Dimensions
(H, D)
19"-System | Weight kg |
|
BLWA 0250-15 | 20 ... 500 MHz | 15 / 18
| 41.8 / 44 ±2 | 20 / 15 | 250 | 2 HU, 430 mm | 12 |
| BLWA 0250-35 | 20 ... 500 MHz | 35 / 40
| 45.4 / 48 ±2 | 20 / 20 | 280 | 2 HU, 430 mm | 13 |
| BLWA 0250-60 | 20 ... 500 MHz | 60 / 70
| 47.8 / 50 ±2 | 20 / 15 | 350 | 2 HU, 430 mm | 13 |
| BLWA 0250-85 | 20 ... 500 MHz | 85 / 100
| 49.3 / 52 ±2 | 20 / 15 | 500 | 3 HU, 430 mm | 18 |
| BLWA 0250-125 | 20 ... 500 MHz | 125 / 135
| 51 / 53 ±2 | 20 / 20 | 1000 | 3 HU, 630 mm | 35 |
| BLWA 0250-250 | 20 ... 500 MHz | 250 / 300
| 54 / 56 ±2 | 20 / 20 | 1250 | 4 HU, 630 mm | 40 |
| BLWA 0250-500 | 20 ... 500 MHz | 500 / 600
| 57 / 59 ±2 | 20 / 20 | 3000 | 4 HU, 630 mm | 45 |
| BLWA 0250-750 | 20 ... 500 MHz | 750 / 800
| 58.8 / 61 ±2 | 20 / 20 | 4500 | 8 HU, 630 mm | 80 |
| BLWA 0250-1000 | 20 ... 500 MHz | 1000 / 1200
| 60 / 62 ±2 | 20 / 20 | 6500 | 9 HU, 630 mm | 95 |
| BLWA 0250-1500 | 20 ... 500 MHz | 1500 / 1650
| 61.8 / 64 ±2 | 20 / 20 | 9000 | 15 HU, 630 mm | 160 |
| BLWA 0250-2000 | 20 ... 500 MHz | 2000 / 2500
| 63 / 65 ±2 | 20 / 20 | 13000 | 18 HU, 800 mm | 185 |
| BLWA 0250-3000 | 20 ... 500 MHz | 3000 / 3500
| 64.8 / 67 ±2 | 20 / 20 | 18000 | 37 HU, 800 mm | 310 |
|
|
For individual data sheets, please click on the above model name
|
1 HU = 44.45 mm
|
STANDARD SPECIFICATIONS
|
Input Power: | 0 dBm (1 mW) max. | Overdrive Protection: | up to +10 dBm for no damage | Input Impedance: | 50 Ohm nominal | Output Impedance: | 50 Ohm nominal | Input VSWR: | <2:1 typ. | Load VSWR: | infinite for no damage (100% mismatch tolerant) | | PN -0.5 dB min. at VSWR 2:1 | |
| Spurious (at PN): | -60 dBc min. (excluding harmonics) | Class of Operation: | A linear or A-B linear |
|
|
GENERAL
|
RF Input: | N-f, standard on rear panel | RF Output: | standard on rear panel
PN up to 1 kW | N-f | PN >1 kW | 7-16-f | PN >2 kW | 13-30-f or 1 5/8"EIA |
| Mains Supply: | Line Power:
<1000 VA | 100 ... 240 V AC ±10% | 47 ... 63 Hz | 1000 ... 3000 VA | 200 ... 240 V AC ±10% | 47 ... 63 Hz | >3000 VA | 3x 400 V AC ±10% | 47 ... 63 Hz |
| Elapsed Time Meter: | via status display | Ambient Temperature: | 0 ... +45 °C | Storage Temperature: | -20 ... +85 °C | Relative Humidity: | up to 95% (non-condensing) | Operating Altitude: | up to 2000 m above sea level | Vibration and Shock: | MIL-STD-810 G | Cooling: | forced air with integral blower
air intake from front, air exhaust at rear |
|
|
OPTIONS
|
A) RF-Sample Ports | I) 3x 208 V AC / 60 Hz | B) External Dual Directional Coupler | L) LAN Remote Control | C) IEEE-488.2 GPIB Remote Control | S) Internal RF Switching Unit | D) Front Panel RF Connectors | R) RS-232C/RS-485 Remote Control | E) RF Power Indication (digital) | U) USB Remote Control | F) Gain Adjustment | W) Liquid Cooling | H) DC Supply | X) External Control of other Amplifiers |
|
BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10 - info@bonn-elektronik.com - www.bonn-elektronik.com
|
BLWA Specifications are subject to change without notice |