BLWA  1.5 ... 30 MHz
Solid State Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BLWA 0103-1001.5 ... 30 MHz 100 / 120
50 / 52 ±220 / 204502 HU, 430 mm14

BLWA 0103-1501.5 ... 30 MHz 150 / 180
51.8 / 54 ±220 / 205002 HU, 430 mm15

BLWA 0103-2501.5 ... 30 MHz 250 / 300
54 / 56 ±220 / 188003 HU, 630 mm18

BLWA 0103-5001.5 ... 30 MHz 500 / 600
57 / 59 ±220 / 1215003 HU, 630 mm28

BLWA 0103-8001.5 ... 30 MHz 800 / 900
59 / 61 ±220 / 1230004 HU, 630 mm38

BLWA 0103-10001.5 ... 30 MHz 1000 / 1200
60 / 62 ±220 / 1245004 HU, 630 mm43

BLWA 0103-15001.5 ... 30 MHz 1500 / 2000
61.8 / 64 ±220 / 1250005 HU, 630 mm62

BLWA 0103-20001.5 ... 30 MHz 2000 / 2500
63 / 65 ±220 / 1270007 HU, 630 mm70

BLWA 0103-30001.5 ... 30 MHz 3000 / 4000
64.8 / 67 ±220 / 1290008 HU, 630 mm75

BLWA 0103-50001.5 ... 30 MHz 5000 / 6000
67 / 69 ±220 / 121800021 HU, 800 mm220

BLWA 0103-100001.5 ... 30 MHz 10000 / 12000
70 / 72 ±220 / 123500037 HU, 800 mm450

BLWA 0103-200001.5 ... 30 MHz 20000 / 22000
73 / 75 ±220 / 12700002x 37 HU, 800 mm950

BLWA 0103-400001.5 ... 30 MHz 40000 / 42000
76 / 78 ±220 / 121400004x 37 HU, 800 mm1950

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-60 dBc min. (excluding harmonics)
Class of Operation:A linear or A-B linear
 
GENERAL

RF Input:N-f, standard on rear panel
RF Output:standard on rear panel
PN up to 1 kWN-f
PN >1 kW 7-16-f
PN >2 kW13-30-f or 1 5/8"EIA
Mains Supply:Line Power:
<1000 VA100 ... 240 V AC ±10%47 ... 63 Hz
1000 ... 3000 VA200 ... 240 V AC ±10%47 ... 63 Hz
>3000 VA3x 400 V AC ±10%47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-25 ... 85 °C
Relative Humidity:up to 95% (non-condensing)
Operating Altitude:up to 2000 m above sea level
Vibration and Shock:MIL-STD-810 G
Cooling:forced air with integral blower
air intake from front, air exhaust at rear
 
OPTIONS

A) RF-Sample PortsL) LAN Remote Control
B) External Dual Directional CouplerP) Precise RMS RF Power Sensor (internal)
C) IEEE-488.2 GPIB Remote ControlR) RS-232C/RS-485 Remote Control
D) Front Panel RF ConnectorsS) Internal RF Switching Unit
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Liquid Cooling
H) DC SupplyX) External Control of other Amplifiers