BTA  9 kHz ... 220 MHz
Hybrid Amplifiers
 
STANDARD MODELS

Model
Frequency Range
Output Power
PN min / typ
W
Gain
min / typ
dB
Harmonics
2nd / 3rd
dBc
Line Power

VA
Dimensions
(H, D)
19"-System
Weight

kg

BTA 0122-20009 kHz ... 220 MHz 2000 / 2200
63 / 66 ±312 / 181500018 HU, 800 mm220

BTA 0122-30009 kHz ... 220 MHz 3000 / 3300
64.8 / 67.5 ±2.512 / 182500032 HU, 800 mm325

For individual data sheets, please click on the above model name
 
1 HU = 44.45 mm
 
STANDARD SPECIFICATIONS

Input Power:0 dBm (1 mW) max.
Overdrive Protection:up to +10 dBm for no damage
Input Impedance:50 Ohm nominal
Output Impedance:50 Ohm nominal
Input VSWR:<2:1 typ.
Load VSWR:
infinite for no damage (100% mismatch tolerant)
PN -0.5 dB min. at VSWR 2:1
Spurious (at PN):-50 dBc typ. (excluding harmonics)
Class of Operation:A-linear
 
GENERAL

RF Input:N-f; standard on rear panel
RF Output:7-16-f; standard on rear panel
Mains Supply:
3x400 V AC47 ... 63 Hz
Elapsed Time Meter:via status display
Ambient Temperature:0 ... +45 °C
Storage Temperature:-20 ... +85 °C
Relative Humidity:up to 95% (non-condensing)
Vibration and Shock:normal laboratory environment
Operating Altitude:up to 2000 m above sea level
Cooling:forced air with integral blower
air intake from bottom, air exhaust at top
 
OPTIONS

A) Sample PortsI) 3x 208 V AC / 60 Hz
B) External Dual Directional CouplerL) LAN Remote Control
C) IEEE-488.2 GPIB Remote ControlS) Internal RF Switching Unit
D) Front Panel RF ConnectorsR) RS-232C Remote Control
E) RF Power Indication (digital)U) USB Remote Control
F) Gain AdjustmentW) Flüssigkühlung (external)
F) Gain AdjustmentX) External Control of other Amplifiers
 

BONN Elektronik GmbH - Ohmstraße 11 - 83607 Holzkirchen - Tel +49 (0)8024/608 83-0
Fax +49 (0)8024/608 83-10   -   info@bonn-elektronik.com  -  www.bonn-elektronik.com
 
 
BTA
Specifications are subject to change without notice